autotelic.build

DESIGN · BUILD · AUTOMATE

DENVER SERVICES

Kitchen Remodel in Denver

Licensed kitchen remodel services for Denver and Denver County. The kitchen your home deserves.

  • Full Design Lifecycle
  • Construction & Tenant Finish
  • Smart Home · A/V · Edge Compute
Kitchen Remodel

The kitchen your home deserves

FREE PLANNING TOOLS

Both tools are free and take a couple of minutes — start in either one.

Local Service

Kitchen Remodel Services in Denver, Colorado

Autotelic provides professional kitchen remodel services throughout Denver and the surrounding Denver County area. Custom kitchen remodels across the Denver metro featuring cabinetry, stone countertops, smart appliances, and integrated lighting design. Commercially licensed and insured. Whether you're in Denver (Colorado's capital city) or nearby communities, our team delivers quality workmanship backed by Colorado licensing and full insurance coverage.

Permits & Licensing

Permits in Denver

Building permits in Denver are issued by Community Planning and Development, and contractor licensing here is municipal — a Denver-licensed contractor pulls Denver permits. We handle permit applications and inspections as part of every project. Authority: City and County of Denver — Community Planning and Development.

Permit Thresholds

Denver permit thresholds

Code reference
Drywall patching or replacement of one sheet no larger than 4 ft by 8 ft.
Code/municipal-code references
Requirements are administered under the Denver Building and Fire Code (2025 edition, effective December 31, 2025, incorporating 2024 I-Codes with local amendments; prior editions referenced similar administrative provisions).
Code reference
Exemptions and permit triggers align with administrative sections (e.g., analogous to IBC/IRC Section 105 or city-specific Admin provisions such as those referenced in policy documents like ADMIN 131/138).Section 105
Code reference
Demolition has a specific reference (Denver Commercial Building Code Section 130.3 for exempted work).Section 130.3
There is a tiered schedule (e.g., $1–$500
$20 permit fee; higher tiers add per-$1,000 amounts with 50% plan review on many ranges); see the full table in the Development Fees policy for exact tiers.

Codes are amended regularly — verify current requirements with City and County of Denver — Community Planning and Development.

Energy Code

Denver energy code quick facts

Code reference
2021 IECC (with local Denver amendments) as adopted in the 2025 Denver Building and Fire Codes / Denver Energy Code (effective December 31, 2025); Denver Green Code (DGC) provisions may also apply to certain commercial/multifamily projects.
Code reference
Denver (Climate Zone 5B) follows the 2021 IECC base with amendments incorporated into the Denver Energy Code (DEC; residential provisions start around p.
Code reference
312 of the code document).
Code reference
The 2025 adoption explicitly incorporates the 2021 IECC for energy (distinct from the 2024 I-codes used for other building/fire provisions).
Code reference
Chapter 5 [RE] / [CE] addresses additions, alterations, repairs, and changes of occupancy to existing buildings.
Code reference
The DGC (2022, effective ~May 2023) is largely voluntary but includes mandatory elements for some larger buildings alongside Energize Denver performance standards (primarily for existing large buildings).
Code reference
Key prescriptive requirements relevant to remodels/additions (drawn from 2021 IECC Table R402.1.3 / equivalent, applicable via Chapter 5 for new envelope work unless otherwise exempted; Denver-specific checklist references confirm use of these tables or U-factor alternatives):
Ceiling/attic insulation
Minimum R-60 (Climate Zone 5).

Codes are amended regularly — verify current requirements with City and County of Denver — Community Planning and Development.

Zoning & Dimensional Standards

Setback & dimensional standards in Denver

Zone-district dimensional standards for Denver, quoted verbatim from the Denver Zoning Code. Knowing your lot's district — and its setbacks, height, and coverage limits — is where every feasibility conversation starts.

E-CC-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code E-CC-3 setback standards (4.3, p.37) — effective 2010-06-25 · View the code

E-MS-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MS-2 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MS-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MS-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MS-5 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MU-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-MU-2.5 setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-MX-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-2 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-2Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-2A setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-3Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-3A setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-Esetback & dimensional standards
StandardRequirement
Primary Street Setback (min)40% E-MS: 60%
Side Street Setback (min)25%

Denver Zoning Code E-MX-E setback standards (4.3, p.39) — effective 2010-06-25 · View the code

E-RH-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-RH-2.5 setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-RX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-RX-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-RX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-RX-5 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-SU-Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-SU-A setback standards (4.3, p.21) — effective 2010-06-25 · View the code

E-SU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-SU-B setback standards (4.3, p.21) — effective 2010-06-25 · View the code

E-SU-Dsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-SU-D setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-SU-Gsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)9,000 sf
Zone Lot Width (min)62.5'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-SU-G setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-TU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-TU-B setback standards (4.3, p.21) — effective 2010-06-25 · View the code

E-TU-Csetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)3' min one side/ 10' min combined
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)5,500 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-TU-C setback standards (4.3, p.21) — effective 2010-06-25 · View the code

G-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-MS-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-MS-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-MS-5 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-MU-12setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)10'
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'

Denver Zoning Code G-MU-12 setback standards (6.3, p.29) — effective 2010-06-25 · View the code

G-MU-20setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)10'
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'

Denver Zoning Code G-MU-20 setback standards (6.3, p.29) — effective 2010-06-25 · View the code

G-MU-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)3' min one side/10' min combined
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-MU-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-MU-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-MU-5 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-MU-8setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-MU-8 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-MX-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-RH-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)15'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Bulk Plane12'

Denver Zoning Code G-RH-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-RO-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)3' min one side/10' min combined
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-RO-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-RO-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-RO-5 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-RX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-RX-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-RX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-RX-5 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

S-CC-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-CC-3 setback standards (3.3, p.29) — effective 2010-06-25 · View the code

S-CC-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)5'

Denver Zoning Code S-CC-5 setback standards (3.3, p.33) — effective 2010-06-25 · View the code

S-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-MS-3 setback standards (3.3, p.29) — effective 2010-06-25 · View the code

S-MU-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)13.1.5.9 or 20' , whichever
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)37.5'
Height in Feet (max)32'/32'
Height in Stories (max)3/3

Denver Zoning Code S-MU-3 setback standards (3.3, p.21) — effective 2010-06-25 · View the code

S-MX-12setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20' 20'/25'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-12 setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-12Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20' 20'/25'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-12A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-MX-2 setback standards (3.3, p.29) — effective 2010-06-25 · View the code

S-MX-2Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)40% Residential Only Buildings: 30%
Side Street Setback (min)25%
Side Interior Setback (min)0'

Denver Zoning Code S-MX-2A setback standards (3.3, p.37) — effective 2010-06-25 · View the code

S-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-MX-3 setback standards (3.3, p.31) — effective 2010-06-25 · View the code

S-MX-3Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)15'

Denver Zoning Code S-MX-3A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-5 setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-5Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-5A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-8Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'

Denver Zoning Code S-MX-8A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-RH-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)37.5'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code S-RH-2.5 setback standards (3.3, p.21) — effective 2010-06-25 · View the code

S-SU-Asetback & dimensional standards
StandardRequirement
Side Interior Setback (min)3' 5'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code S-SU-A setback standards (3.3, p.19) — effective 2010-06-25 · View the code

S-SU-FAsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10' 5'/15'
Side Interior Setback (min)5'/15'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)8,500 sf
Zone Lot Width (min)62.5'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'

Denver Zoning Code S-SU-FA setback standards (3.3, p.19) — effective 2010-06-25 · View the code

S-SU-Isetback & dimensional standards
StandardRequirement
Side Street Setback (min)5'
Zone Lot Area (min)12,000 sf
Zone Lot Width (min)62.5'
Height in Feet (max)30'/30'
Height in Stories (max)3/3
Bulk Plane10'/10' 10'/10'

Denver Zoning Code S-SU-I setback standards (3.3, p.19) — effective 2010-06-25 · View the code

U-MS-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MS-2 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MS-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MS-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MS-5 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MX-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MX-2 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MX-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-RH-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)10'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-RH-2.5 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-RH-3Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)10'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-RH-3A setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-RX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-RX-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-RX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-RX-5 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-SU-Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-A setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-A2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-A2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-B setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-B2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-B2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Csetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Interior Setback (min)3' min one 10' min combined
Zone Lot Area (min)5,500 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-C setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-C2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3' min one 10' min combined
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)5,500 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-C2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Esetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)7,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-E setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Hsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)10,000 sf
Zone Lot Width (min)75'
Height in Feet (max)30'/17'
Height in Stories (max)3/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-H setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-TU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-TU-B setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-TU-B2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-TU-B2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-TU-Csetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)10'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-TU-C setback standards (5.3, p.19) — effective 2010-06-25 · View the code

Verify current requirements with the jurisdiction — informational reference only. Standards vary by overlay, lot, and use; we confirm the exact rules for your property during feasibility.

text

What a kitchen remodel usually includes

A residential kitchen remodel in the Denver metro can mean new cabinets and counters in the existing layout, or a full gut that relocates the sink, dishwasher, range, lighting, and openings to adjacent rooms. Scope commonly covers demolition, plumbing and electrical rough-in when utilities move, cabinetry, countertops, backsplash, flooring transitions, lighting, and finish trim. A municipally licensed Denver general contractor coordinates the overall remodel and the licensed specialty trades required for plumbing, electrical, gas, and related work. Cost is project-specific and depends on whether utilities move, structural openings, finish selections, and access.

text

Layout decisions that change the build

Keeping fixtures in place usually shortens rough-in and inspection scope. Moving a sink, adding an island with water or power, or opening a wall into the living space adds plumbing, electrical, and sometimes structural work. Island plans should confirm floor structure, receptacle needs, and whether a sink or dishwasher will be included. Lock cabinet and counter selections early enough to drive rough dimensions before drywall closes. Long-lead materials often set the critical path after demolition.

text

Permits and who coordinates the work

City and County of Denver Community Planning and Development (CPD) generally requires permits when a kitchen remodel alters the floor plan, affects structure, or relocates electrical or plumbing fixtures. Like-for-like cabinet, counter, flooring, and fixture replacements in the same locations without system changes are often treated as not needing a building permit. Trade work may use CPD Quick Permits when eligible. Cities and counties license general contractors. Colorado has no statewide general contractor license. Electrical and plumbing are state-regulated specialty trades. Autotelic acts as a municipally licensed Denver general contractor and coordinates licensed specialty trades for the remodel package.

text

Energy, lead-safe, and inspection sequencing

New lighting installed in an interior residential alteration should follow Denver Energy Code requirements for lighting in alterations. Pre-1978 homes may trigger EPA Renovation, Repair and Painting rules when painted surfaces are disturbed during demo or opening walls. A practical sequence is demo, rough trades, required inspections, close-up, cabinets and counters, finals, then punch. Discovery items such as damaged framing or outdated wiring should be approved before they expand the finish schedule.

FAQ

Common questions

Do I need a Denver permit for a kitchen remodel?

Often yes if you move plumbing or electrical, change gas lines, alter structure, or change the floor plan. Cosmetic-only replacements in the same locations frequently do not need a building permit. City and County of Denver CPD is the building-permit authority inside Denver.

Who handles kitchen remodel permits and licensing?

A municipally licensed Denver general contractor coordinates the project and the licensed specialty trades required for plumbing, electrical, and related work. CPD issues building and trade permits as applicable. Colorado has no statewide general contractor license.

Does moving the sink or range change the project much?

Yes. Relocating water, drain, vent, gas, or electrical feeds adds rough-in, inspections, and sometimes structural work. Keeping appliances and the sink in place usually simplifies the schedule.

What should be decided before demolition?

Final layout, appliance list, whether walls open, cabinet and counter approach, lighting plan, and flooring transitions. Locked selections reduce mid-project changes after rough-in.

What information helps define an accurate kitchen remodel scope?

Photos or measurements, whether utilities will move, desired finish level, any known electrical panel limits, and the city or county for permitting. Sketches of the target layout help when walls will open.

Service Area

Serving Denver and Denver County

We serve Denver, CO and all surrounding Denver metro communities. Our team is based in Denver and operates throughout the Front Range, from Castle Rock to Longmont and everywhere in between. Contact us for a free estimate on your Denver project.

FAQ

Common questions

Do I need a permit to remodel my kitchen?

Usually yes — any work touching plumbing, electrical, or structure needs a permit from your city or county building department. Permitting in Colorado is municipal, and we handle the application and inspections as part of the project.

How does the estimate work?

Tell us about your kitchen through the form or a call. Use the Instant Estimate tool for a real, scored estimate in about two minutes — free, and without a pushy sales visit.

Do you handle design as well as construction?

Yes — we are a design-build contractor, so layout, materials, cabinetry, and trades coordination run through one team from drawings to final walk-through.

How It Runs

01

Survey

02

Design

03

Build

04

Verify

DESIGN SERVICES

CONSTRUCTION

TECHNOLOGY

TRUSTED TO BUILD FOR

  • Punch Bowl SocialFirst four locations
  • Spectrum RetirementSenior living communities
  • Denver HighlandsFirst modular custom home

Let's design your perfect Kitchen Remodel together

Get a personalized estimate in about 2 minutes — no pressure, no obligation.

Licensed & Insured ContractorVeteran-Owned

How This Works (2 minutes)

  1. 1Tell us about your project (30 seconds)
  2. 2Answer a few quick questions for an accurate estimate (60 seconds)
  3. 3Get your personalized estimate instantly (30 seconds)

No pressure. No obligation. No spam calls. If we're not the right fit, we'll tell you — and even recommend someone who is.