DESIGN · BUILD · AUTOMATE
DENVER SERVICES
Bathroom Remodel in Denver
Licensed bathroom remodel services for Denver and Denver County. Transform your bathroom into a retreat.
- Full Design Lifecycle
- Construction & Tenant Finish
- Smart Home · A/V · Edge Compute

Transform your bathroom into a retreat
EVERY PROJECT STARTS WITH DESIGN
Local Service
Bathroom Remodel Services in Denver, Colorado
Autotelic provides professional bathroom remodel services throughout Denver and the surrounding Denver County area. Full bathroom remodels across the Denver metro from cosmetic refreshes to luxury gut renovations. Tile, fixtures, vanities, and Kerdi waterproofing. Whether you're in Denver (Colorado's capital city) or nearby communities, our team delivers quality workmanship backed by Colorado licensing and full insurance coverage.
Permits & Licensing
Permits in Denver
Building permits in Denver are issued by Community Planning and Development, and contractor licensing here is municipal — a Denver-licensed contractor pulls Denver permits. We handle permit applications and inspections as part of every project. Authority: City and County of Denver — Community Planning and Development.
Permit Thresholds
Denver permit thresholds
- Code reference
- Drywall patching or replacement of one sheet no larger than 4 ft by 8 ft.
- Code/municipal-code references
- Requirements are administered under the Denver Building and Fire Code (2025 edition, effective December 31, 2025, incorporating 2024 I-Codes with local amendments; prior editions referenced similar administrative provisions).
- Code reference
- Exemptions and permit triggers align with administrative sections (e.g., analogous to IBC/IRC Section 105 or city-specific Admin provisions such as those referenced in policy documents like ADMIN 131/138).Section 105
- Code reference
- Demolition has a specific reference (Denver Commercial Building Code Section 130.3 for exempted work).Section 130.3
- There is a tiered schedule (e.g., $1–$500
- $20 permit fee; higher tiers add per-$1,000 amounts with 50% plan review on many ranges); see the full table in the Development Fees policy for exact tiers.
Codes are amended regularly — verify current requirements with City and County of Denver — Community Planning and Development.
Energy Code
Denver energy code quick facts
- Code reference
- 2021 IECC (with local Denver amendments) as adopted in the 2025 Denver Building and Fire Codes / Denver Energy Code (effective December 31, 2025); Denver Green Code (DGC) provisions may also apply to certain commercial/multifamily projects.
- Code reference
- Denver (Climate Zone 5B) follows the 2021 IECC base with amendments incorporated into the Denver Energy Code (DEC; residential provisions start around p.
- Code reference
- 312 of the code document).
- Code reference
- The 2025 adoption explicitly incorporates the 2021 IECC for energy (distinct from the 2024 I-codes used for other building/fire provisions).
- Code reference
- Chapter 5 [RE] / [CE] addresses additions, alterations, repairs, and changes of occupancy to existing buildings.
- Code reference
- The DGC (2022, effective ~May 2023) is largely voluntary but includes mandatory elements for some larger buildings alongside Energize Denver performance standards (primarily for existing large buildings).
- Code reference
- Key prescriptive requirements relevant to remodels/additions (drawn from 2021 IECC Table R402.1.3 / equivalent, applicable via Chapter 5 for new envelope work unless otherwise exempted; Denver-specific checklist references confirm use of these tables or U-factor alternatives):
- Ceiling/attic insulation
- Minimum R-60 (Climate Zone 5).
Codes are amended regularly — verify current requirements with City and County of Denver — Community Planning and Development.
Zoning & Dimensional Standards
Setback & dimensional standards in Denver
Zone-district dimensional standards for Denver, quoted verbatim from the Denver Zoning Code. Knowing your lot's district — and its setbacks, height, and coverage limits — is where every feasibility conversation starts.
E-CC-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 0' |
| Side Street Setback (min) | 0' |
| Side Interior Setback (min) | 0' |
Denver Zoning Code E-CC-3 setback standards (4.3, p.37) — effective 2010-06-25 · View the code
E-MS-2setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code E-MS-2 setback standards (4.3, p.33) — effective 2010-06-25 · View the code
E-MS-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code E-MS-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code
E-MS-5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code E-MS-5 setback standards (4.3, p.33) — effective 2010-06-25 · View the code
E-MU-2.5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 7.5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 6,000 sf |
| Zone Lot Width (min) | 50' |
| Height in Feet (max) | 30'/30' |
| Height in Stories (max) | 2.5/2.5 |
| Bulk Plane | 10'/10' |
Denver Zoning Code E-MU-2.5 setback standards (4.3, p.19) — effective 2010-06-25 · View the code
E-MX-2setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code E-MX-2 setback standards (4.3, p.33) — effective 2010-06-25 · View the code
E-MX-2Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code E-MX-2A setback standards (4.3, p.33) — effective 2010-06-25 · View the code
E-MX-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code E-MX-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code
E-MX-3Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code E-MX-3A setback standards (4.3, p.33) — effective 2010-06-25 · View the code
E-MX-Esetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 40% E-MS: 60% |
| Side Street Setback (min) | 25% |
Denver Zoning Code E-MX-E setback standards (4.3, p.39) — effective 2010-06-25 · View the code
E-RH-2.5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 7.5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 6,000 sf |
| Zone Lot Width (min) | 50' |
| Height in Feet (max) | 30'/30' |
| Height in Stories (max) | 2.5/2.5 |
| Bulk Plane | 10'/10' |
Denver Zoning Code E-RH-2.5 setback standards (4.3, p.19) — effective 2010-06-25 · View the code
E-RX-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code E-RX-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code
E-RX-5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code E-RX-5 setback standards (4.3, p.33) — effective 2010-06-25 · View the code
E-SU-Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Rear Setback where no alley (min) | 12' 12' 20' 20' 20' |
| Rear Setback where alley abuts (min) | 3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code E-SU-A setback standards (4.3, p.21) — effective 2010-06-25 · View the code
E-SU-Bsetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Rear Setback where no alley (min) | 12' 12' 20' 20' 20' |
| Rear Setback where alley abuts (min) | 3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10' |
| Zone Lot Area (min) | 4,500 sf |
| Zone Lot Width (min) | 35' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code E-SU-B setback standards (4.3, p.21) — effective 2010-06-25 · View the code
E-SU-Dsetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 6,000 sf |
| Zone Lot Width (min) | 50' |
| Height in Feet (max) | 30'/30' |
| Height in Stories (max) | 2.5/2.5 |
| Bulk Plane | 10'/10' |
Denver Zoning Code E-SU-D setback standards (4.3, p.19) — effective 2010-06-25 · View the code
E-SU-Gsetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Rear Setback where no alley (min) | 12' 12' 20' 20' 20' |
| Rear Setback where alley abuts (min) | 3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 9,000 sf |
| Zone Lot Width (min) | 62.5' |
| Height in Feet (max) | 30'/30' |
| Height in Stories (max) | 2.5/2.5 |
| Bulk Plane | 10'/10' |
Denver Zoning Code E-SU-G setback standards (4.3, p.19) — effective 2010-06-25 · View the code
E-TU-Bsetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 3' |
| Side Interior Setback (min) | 3' |
| Rear Setback where no alley (min) | 12' 12' 20' 20' 20' |
| Rear Setback where alley abuts (min) | 3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 4,500 sf |
| Zone Lot Width (min) | 35' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code E-TU-B setback standards (4.3, p.21) — effective 2010-06-25 · View the code
E-TU-Csetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 3' min one side/ 10' min combined |
| Rear Setback where no alley (min) | 12' 12' 20' 20' 20' |
| Rear Setback where alley abuts (min) | 3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 5,500 sf |
| Zone Lot Width (min) | 50' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code E-TU-C setback standards (4.3, p.21) — effective 2010-06-25 · View the code
G-MS-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code G-MS-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code
G-MS-5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code G-MS-5 setback standards (6.3, p.27) — effective 2010-06-25 · View the code
G-MU-12setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 7.5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 10' |
| Zone Lot Area (min) | 6,000 sf |
| Zone Lot Width (min) | 50' |
Denver Zoning Code G-MU-12 setback standards (6.3, p.29) — effective 2010-06-25 · View the code
G-MU-20setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 7.5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 10' |
| Zone Lot Area (min) | 6,000 sf |
| Zone Lot Width (min) | 50' |
Denver Zoning Code G-MU-20 setback standards (6.3, p.29) — effective 2010-06-25 · View the code
G-MU-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 3' min one side/10' min combined |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
Denver Zoning Code G-MU-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code
G-MU-5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
Denver Zoning Code G-MU-5 setback standards (6.3, p.17) — effective 2010-06-25 · View the code
G-MU-8setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 7.5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 40% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
Denver Zoning Code G-MU-8 setback standards (6.3, p.17) — effective 2010-06-25 · View the code
G-MX-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code G-MX-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code
G-RH-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 15' |
| Side Interior Setback (min) | 3' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 60% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
| Bulk Plane | 12' |
Denver Zoning Code G-RH-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code
G-RO-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 3' min one side/10' min combined |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
Denver Zoning Code G-RO-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code
G-RO-5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
Denver Zoning Code G-RO-5 setback standards (6.3, p.17) — effective 2010-06-25 · View the code
G-RX-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code G-RX-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code
G-RX-5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code G-RX-5 setback standards (6.3, p.27) — effective 2010-06-25 · View the code
S-CC-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 0' |
| Side Street Setback (min) | 0' |
| Side Interior Setback (min) | 0' |
Denver Zoning Code S-CC-3 setback standards (3.3, p.29) — effective 2010-06-25 · View the code
S-CC-5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 0' |
| Side Street Setback (min) | 0' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code S-CC-5 setback standards (3.3, p.33) — effective 2010-06-25 · View the code
S-MS-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 0' |
| Side Street Setback (min) | 0' |
| Side Interior Setback (min) | 0' |
Denver Zoning Code S-MS-3 setback standards (3.3, p.29) — effective 2010-06-25 · View the code
S-MU-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 13.1.5.9 or 20' , whichever |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 50% |
| Zone Lot Area (min) | 4,500 sf |
| Zone Lot Width (min) | 37.5' |
| Height in Feet (max) | 32'/32' |
| Height in Stories (max) | 3/3 |
Denver Zoning Code S-MU-3 setback standards (3.3, p.21) — effective 2010-06-25 · View the code
S-MX-12setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' 20'/25' |
| Side Interior Setback (min) | 35'/40' |
Denver Zoning Code S-MX-12 setback standards (3.3, p.39) — effective 2010-06-25 · View the code
S-MX-12Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' 20'/25' |
| Side Interior Setback (min) | 35'/40' |
Denver Zoning Code S-MX-12A setback standards (3.3, p.39) — effective 2010-06-25 · View the code
S-MX-2setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 0' |
| Side Street Setback (min) | 0' |
| Side Interior Setback (min) | 0' |
Denver Zoning Code S-MX-2 setback standards (3.3, p.29) — effective 2010-06-25 · View the code
S-MX-2Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 40% Residential Only Buildings: 30% |
| Side Street Setback (min) | 25% |
| Side Interior Setback (min) | 0' |
Denver Zoning Code S-MX-2A setback standards (3.3, p.37) — effective 2010-06-25 · View the code
S-MX-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 0' |
| Side Street Setback (min) | 0' |
| Side Interior Setback (min) | 0' |
Denver Zoning Code S-MX-3 setback standards (3.3, p.31) — effective 2010-06-25 · View the code
S-MX-3Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 15' |
Denver Zoning Code S-MX-3A setback standards (3.3, p.39) — effective 2010-06-25 · View the code
S-MX-5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Interior Setback (min) | 35'/40' |
Denver Zoning Code S-MX-5 setback standards (3.3, p.39) — effective 2010-06-25 · View the code
S-MX-5Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
| Side Interior Setback (min) | 35'/40' |
Denver Zoning Code S-MX-5A setback standards (3.3, p.39) — effective 2010-06-25 · View the code
S-MX-8Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 20' |
Denver Zoning Code S-MX-8A setback standards (3.3, p.39) — effective 2010-06-25 · View the code
S-RH-2.5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 50% |
| Zone Lot Area (min) | 4,500 sf |
| Zone Lot Width (min) | 37.5' |
| Height in Feet (max) | 30'/30' |
| Height in Stories (max) | 2.5/2.5 |
| Bulk Plane | 10'/10' |
Denver Zoning Code S-RH-2.5 setback standards (3.3, p.21) — effective 2010-06-25 · View the code
S-SU-Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Side Interior Setback (min) | 3' 5' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 50% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
| Height in Feet (max) | 30'/30' |
| Height in Stories (max) | 2.5/2.5 |
| Bulk Plane | 10'/10' |
Denver Zoning Code S-SU-A setback standards (3.3, p.19) — effective 2010-06-25 · View the code
S-SU-FAsetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' 5'/15' |
| Side Interior Setback (min) | 5'/15' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 50% |
| Zone Lot Area (min) | 8,500 sf |
| Zone Lot Width (min) | 62.5' |
| Height in Feet (max) | 30'/30' |
| Height in Stories (max) | 2.5/2.5 |
| Bulk Plane | 10' |
Denver Zoning Code S-SU-FA setback standards (3.3, p.19) — effective 2010-06-25 · View the code
S-SU-Isetback & dimensional standards
| Standard | Requirement |
|---|---|
| Side Street Setback (min) | 5' |
| Zone Lot Area (min) | 12,000 sf |
| Zone Lot Width (min) | 62.5' |
| Height in Feet (max) | 30'/30' |
| Height in Stories (max) | 3/3 |
| Bulk Plane | 10'/10' 10'/10' |
Denver Zoning Code S-SU-I setback standards (3.3, p.19) — effective 2010-06-25 · View the code
U-MS-2setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code U-MS-2 setback standards (5.3, p.27) — effective 2010-06-25 · View the code
U-MS-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code U-MS-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code
U-MS-5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code U-MS-5 setback standards (5.3, p.27) — effective 2010-06-25 · View the code
U-MX-2setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code U-MX-2 setback standards (5.3, p.27) — effective 2010-06-25 · View the code
U-MX-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code U-MX-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code
U-RH-2.5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 10' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 40% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-RH-2.5 setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-RH-3Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 10' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 40% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-RH-3A setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-RX-3setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code U-RX-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code
U-RX-5setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 7.5' |
| Side Interior Setback (min) | 5' |
Denver Zoning Code U-RX-5 setback standards (5.3, p.27) — effective 2010-06-25 · View the code
U-SU-Asetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 3' |
| Side Interior Setback (min) | 3' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 60% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-SU-A setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-SU-A2setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 3' |
| Side Interior Setback (min) | 3' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 60% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-SU-A2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-SU-Bsetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Zone Lot Area (min) | 4,500 sf |
| Zone Lot Width (min) | 35' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-SU-B setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-SU-B2setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 3' |
| Side Interior Setback (min) | 3' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 60% |
| Zone Lot Area (min) | 4,500 sf |
| Zone Lot Width (min) | 35' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-SU-B2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-SU-Csetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Interior Setback (min) | 3' min one 10' min combined |
| Zone Lot Area (min) | 5,500 sf |
| Zone Lot Width (min) | 50' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-SU-C setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-SU-C2setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 3' |
| Side Interior Setback (min) | 3' min one 10' min combined |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 60% |
| Zone Lot Area (min) | 5,500 sf |
| Zone Lot Width (min) | 50' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-SU-C2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-SU-Esetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 7,000 sf |
| Zone Lot Width (min) | 50' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-SU-E setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-SU-Hsetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 5' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 45% |
| Zone Lot Area (min) | 10,000 sf |
| Zone Lot Width (min) | 75' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 3/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-SU-H setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-TU-Bsetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 3' |
| Side Interior Setback (min) | 3' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 60% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-TU-B setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-TU-B2setback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 3' |
| Side Interior Setback (min) | 3' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 60% |
| Zone Lot Area (min) | 3,000 sf |
| Zone Lot Width (min) | 25' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-TU-B2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code
U-TU-Csetback & dimensional standards
| Standard | Requirement |
|---|---|
| Primary Street Setback (min) | 10' |
| Side Street Setback (min) | 5' |
| Side Interior Setback (min) | 10' |
| Rear Setback where no alley (min) | 20' |
| Rear Setback where alley abuts (min) | 12' |
| Building Coverage (max) | 40% |
| Zone Lot Area (min) | 4,500 sf |
| Zone Lot Width (min) | 35' |
| Height in Feet (max) | 30'/17' |
| Height in Stories (max) | 2.5/1 |
| Bulk Plane | 17'/10' |
Denver Zoning Code U-TU-C setback standards (5.3, p.19) — effective 2010-06-25 · View the code
Verify current requirements with the jurisdiction — informational reference only. Standards vary by overlay, lot, and use; we confirm the exact rules for your property during feasibility.
text
What a Bathroom Remodel Usually Includes
A residential bathroom remodel in the Denver metro can range from a surface refresh to a full layout change. Typical permitted scopes often include demolition of existing finishes and fixtures, rough-in of relocated or new plumbing and electrical, framing or structural adjustments when needed, waterproofing in wet areas, insulation and substrate prep, then finish work with new fixtures, surfaces, and ventilation. Projects vary widely. Like-for-like fixture swaps or finish updates may be relatively limited. Tub-to-shower conversions, moving walls, relocating a toilet or vanity, adding a second sink, or changing door and window openings usually expand both construction scope and permit needs. The right plan starts with how the bathroom needs to function every day—storage, accessibility, lighting, and moisture control—not just how it looks on day one.
text
Permits and Inspections in Denver
For single-family and duplex projects in the City and County of Denver, residential bathroom remodel permits and inspections are handled through Community Planning and Development (CPD), including Plan Review, Permits, and Inspections. Applications are submitted and tracked through Denver’s e-permits portal. A building or construction permit is typically required when work alters the floor plan, involves structural changes such as load-bearing walls, adds or resizes doors, windows, skylights, or egress openings, reroutes ductwork, or relocates or adds electrical or plumbing fixtures. Like-for-like replacements of existing cabinets, countertops, flooring, ventilation, or plumbing and electrical fixtures generally do not require a permit. Trade permits for electrical, plumbing, and mechanical work are often needed in addition to a building permit. Some trade work may qualify as quick permits without full plan review when conditions are met. Homeowners may apply directly if eligible, but contractors commonly manage the process. Inspections usually occur at key stages—such as rough-in for plumbing, electrical, and mechanical; framing when applicable; and final—to confirm the work matches approved plans and applicable codes. Unpermitted work can lead to stop-work orders, increased fees, fines, or liens.
text
Code Considerations That Matter in a Bathroom
Denver’s current building and fire codes, effective December 31, 2025, incorporate the 2024 International Residential Code for one- and two-family dwellings, along with the 2024 International Plumbing Code, International Mechanical Code, and related standards, plus Denver-specific amendments. Energy requirements reference the 2021 IECC. Bathroom projects commonly involve plumbing installation requirements such as proper pipe sizing, venting to prevent trap problems, drainage, and backflow prevention. Mechanical ventilation is also a frequent focus: bathrooms and toilet rooms generally need intermittent exhaust of at least 50 cfm or continuous exhaust of at least 20 cfm. Electrical work in wet locations typically requires GFCI protection. Structural alterations must follow residential code provisions for load-bearing elements. Moisture management, waterproofing in showers and other wet zones, and indoor air quality through effective exhaust are practical compliance issues—not just finish details. Exact requirements depend on the property, scope, and current CPD interpretation. Official Denver CPD resources and the e-permits system are the source of truth for a specific project.
text
How a General Contractor Coordinates the Work
As a municipally licensed Denver general contractor, we coordinate the overall remodel and the licensed specialty trades needed for plumbing, electrical, mechanical, and other permitted scopes. That includes planning the sequence of demolition, rough-in, inspections, waterproofing, finishes, and final closeout so the project moves in a code-aware order. Homeowners should expect clear discussion of what is being changed, whether walls or fixtures are moving, how wet areas will be waterproofed, and who is responsible for permit applications and inspection scheduling. When specialty trade permits are required, those trades are coordinated under the general contractor’s project management rather than treated as disconnected side jobs.
text
What Homeowners Should Evaluate Before and During a Remodel
Before selecting a path forward, review whether the planned work is likely to need a building permit, trade permits, or both. Confirm that required permits will be obtained and that rough-in and final inspections will be completed and documented. Ask how layout changes, structural openings, plumbing moves, electrical changes, and exhaust upgrades will be handled under current Denver-adopted codes. Also evaluate what is happening behind the finishes—especially in older homes—such as existing plumbing condition, electrical capacity and protection, moisture damage, and ventilation performance. Review plans and any mid-project changes for continued code compliance. Red flags include pressure to skip permits on work that relocates fixtures, alters structure, or changes the floor plan, or a lack of inspection documentation at the end of the job.
text
Materials and Methods That Support a Durable Bathroom
Official sources do not prescribe a single product list for every bathroom remodel. Durable results depend on code-compliant fixtures and components, moisture-resistant assemblies in wet zones, properly rated electrical devices, and installation methods that follow manufacturer instructions and applicable plumbing, mechanical, and residential codes. In practice, that often means careful substrate prep, continuous waterproofing in showers, correct slope and drainage details, sealed transitions at floors and walls, and exhaust that actually removes moisture from the room. Finish choices matter for maintenance and appearance, but the long-term performance of a bathroom is usually determined by the rough-in, waterproofing, and ventilation work that is no longer visible once the project is complete.
FAQ
Common questions
Do I need a permit for a bathroom remodel in Denver?
Often yes, depending on scope. In the City and County of Denver, a building or construction permit is typically required for floor-plan changes, structural work, added or resized openings, duct reroutes, or relocated or added plumbing or electrical fixtures. Like-for-like replacements of existing cabinets, countertops, flooring, ventilation, or fixtures generally do not require a permit. Trade permits may still apply.
Who handles the plumbing, electrical, and mechanical permits and licensing?
A municipally licensed Denver general contractor coordinates the project and works with licensed specialty trades for plumbing, electrical, mechanical, and related permitted work. Trade permits are commonly pulled in addition to any building permit, and some may qualify as quick permits when allowed by the city.
What inspections are common on a residential bathroom remodel?
Inspections are typically required at key stages such as plumbing, electrical, and mechanical rough-in; framing if structural work is involved; and a final inspection. Inspectors verify that work matches approved plans and applicable codes before the project is closed out.
What building codes apply to bathroom remodels in Denver?
Denver’s building and fire codes effective December 31, 2025 incorporate the 2024 IRC for one- and two-family dwellings, along with the 2024 IPC and IMC and Denver amendments. Energy requirements reference the 2021 IECC. Bathroom projects commonly involve plumbing, ventilation, GFCI protection in wet areas, moisture control, and any structural provisions that apply to the scope.
What bathroom ventilation is typically required?
Under the mechanical code framework used in Denver, bathrooms and toilet rooms generally need intermittent exhaust of at least 50 cfm or continuous exhaust of at least 20 cfm. Proper exhaust helps manage moisture and indoor air quality after finishes and fixtures are installed.
What should I look for if a bathroom was remodeled without clear permit records?
Look for documentation of permits and passed inspections, especially for relocated fixtures, structural changes, or electrical and plumbing rough-in. Unpermitted work can lead to enforcement issues later. A professional evaluation of concealed plumbing, electrical protection, waterproofing, and ventilation is especially important in older homes or when records are incomplete.
Service Area
Serving Denver and Denver County
We serve Denver, CO and all surrounding Denver metro communities. Our team is based in Denver and operates throughout the Front Range, from Castle Rock to Longmont and everywhere in between. Contact us for a free estimate on your Denver project.
FAQ
Common questions
Do bathroom remodels need permits?
Almost always — moving plumbing, changing electrical, or altering walls triggers a municipal permit. We pull the permit with your city or county and schedule the inspections.
Can you renovate multiple bathrooms at once?
Yes. We regularly run multi-bath renovation packages and sequence the work so you keep at least one working bathroom throughout.
How fast can it start?
You will hear from us in minutes and have an estimate within 48 hours. Start dates depend on permit turnaround in your city and material lead times, which we lay out in the proposal.
How It Runs
01
Survey
02
Design
03
Build
04
Verify
DESIGN SERVICES
Discovery & Site Analysis
Needs + preference programming, site survey, as-built documentation, feasibility.
We walk, measure, and photograph your property — existing conditions, utilities, structure, and constraints. You get the as-built documentation and feasibility read that every later decision rests on.
Learn more →Concept Design & Space Planning
Schematic design, floor plan studies, layout options.
Your scope becomes schematic floor plans you can compare side by side — circulation, daylight, adjacencies, and what each option does to the budget. Layout decisions happen on paper, where changes are cheap.
Learn more →Architectural Design & 3D Renderings
Design development, materials + finishes, photorealistic visualization.
The chosen concept resolves into materials, finishes, fixtures, and lighting — with the automation layer drawn in. Photorealistic renderings let you walk the space and adjust before anything is priced.
Learn more →Construction Documents & Permitting
Full CD sets, structural + MEP engineering coordination, permit-ready drawings.
Approved designs become coordinated architectural, structural, and MEP sheets — the set your jurisdiction permits from and trades build from. We submit, track, and answer review comments.
Learn more →CONSTRUCTION
New Construction & Custom Homes
Ground-up homes and light commercial, dirt to keys.
Ground-up residential and light commercial builds — foundations through finishes, including modular and steel construction. One accountable builder from dirt to keys.
Learn more →Remodels & Additions
Kitchens, baths, basements, pop-tops, whole-home.
Kitchens, baths, basements, pop-tops, and whole-home renovations that respect the house you already have. We handle structure, permits, and the dust.
Learn more →Commercial Tenant Finish & Build-Outs
Shells to working spaces — retail, office, restaurant, school.
Raw shells become working spaces — showrooms, offices, restaurants, schools. Dealer-spec finishes, code compliance, and opening dates held.
Learn more →ADUs & Modular Construction
Backyard cottages, garage conversions, factory-built homes.
Backyard cottages, garage conversions, and factory-built homes — zoning, design, permits, and set. Denver’s ADU rules are a specialty, not a surprise.
Learn more →Outdoor Living & Patio Structures
Decks, pergolas, and dining patios built for Colorado weather.
Decks, pergolas, and dining patios engineered for Colorado sun, snow, and hail — structure, shade, and drainage done right the first time.
Learn more →TECHNOLOGY
Smart Home Automation
Lighting, shades, climate, audio, security — one interface.
Whole-home control of lighting, shades, climate, audio, and security from a single interface — Crestron, Lutron, Savant, and Control4 designed in, not bolted on.
Learn more →A/V Systems
Theaters, distributed audio, video walls, commercial sound.
Theaters, distributed audio, video walls, and commercial sound — designed, installed, and tuned by the same team for over 20 years.
Learn more →Control Systems
Custom programming — scenes and schedules that fit the space.
Every subsystem brought into one elegant interface — custom programming for homes and venues, with scenes and schedules that match how the space is actually used.
Learn more →Networking & Edge Compute
Enterprise Wi-Fi, structured cabling, racks, on-prem compute.
Enterprise-grade Wi-Fi, structured cabling, racks, and on-premise compute — the backbone that makes everything else reliable, including our own Barbot platform.
Learn more →Solar & Energy Storage
Solar arrays, Tesla Powerwall, EV charging — certified install.
Solar arrays, Tesla Powerwall, and EV charging designed and installed by a Tesla Energy Certified team — roof, electrical, and app in one scope.
Learn more →TRUSTED TO BUILD FOR
- Punch Bowl SocialFirst four locations
- Spectrum RetirementSenior living communities
- Denver HighlandsFirst modular custom home
Explore
Also serving
Explore