What Denver requires

Code reference: Exemptions and permit triggers align with administrative sections (e.g., analogous to IBC/IRC Section 105 or city-specific Admin provisions such as those referenced in policy documents like ADMIN 131/138). §105

See full local requirements ↓
  • Full Design Lifecycle
  • Construction & Tenant Finish
  • Smart Home · A/V · Edge Compute
Commercial Tenant Finish

Get your business open, on time

Jobs you can book online

Pick your job and choose a time.

Pay when you book. We confirm within 24 hours or refund you in full.

  • Commercial Tenant-Finish Punch Visit

    $149 visit fee — credited toward the work

    GC walkthrough of a commercial space to document and price punch-list or small tenant-improvement scope, with a written proposal.

    Pay when you book · morning (8–12) or afternoon (12–4)

    What's included

    GC walkthrough of a commercial space to document and price punch-list or small tenant-improvement scope, with a written proposal. The $149 fee applies toward any contracted work.

  • Commercial TI Walkthrough

    A licensed GC walks your commercial space and flags code, ADA, MEP, and buildout cost drivers for your tenant improvement.

    Pay when you book · morning (8–12) or afternoon (12–4)

    What's included

    A licensed GC walks your commercial space and flags code, ADA, MEP, and buildout cost drivers for your tenant improvement. Includes a written summary of scope items and rough-order pricing.

FREE PLANNING TOOLS

Both tools are free and take a couple of minutes — start in either one.

Local Service

Commercial Tenant Finish Services in Denver, Colorado

Autotelic provides professional commercial tenant finish services throughout Denver and the surrounding Denver County area. Commercial tenant improvement buildouts across the Denver metro — offices, retail, medical, and restaurant spaces with fast-track scheduling. Commercially licensed and insured. Whether you're in Denver (Colorado's capital city) or nearby communities, our team delivers quality workmanship backed by Colorado licensing and full insurance coverage.

A recent build

Powersports dealership tenant finish

Parker · 2017

Delivery
Commercial tenant finish
Opened
Summer 2017
Program
Showroom · service · parts · lounge
  • High-bay showroom — stained/polished concrete, dealer-spec paint package, suspended track lighting, exposed painted structure, full-height storefront glazing with clerestory windows
  • Service department — sealed/epoxy floor, two-tone wainscot, gas unit heater, pallet racking for parts, lift-table service bays
  • Customer retail area — navy feature walls, curved reception/parts counter, customer lounge with bar-height seating
  • Full interior build — framing/drywall, high-bay HVAC with exposed spiral duct, electrical + lighting, life-safety/exits, finishes throughout

The dealership opened summer 2017 — delivered with the showroom staged with inventory and the service department in operation.

Finished high-bay showroom with polished concrete floors and powersports inventory staged
Showroom at delivery — polished concrete, dealer-spec striping, inventory staged
Showroom looking toward the full-height storefront glazing
Showroom toward the storefront glazing
Finished service department with ATVs staged on the shop floor
Service department — sealed floors, racking, and service bays in operation
Parts counter and customer lounge staged for opening
Parts counter + customer lounge
The same high-bay shell mid-finish — paint and ductwork in progress
Mid-finish — the same shell during construction

Permits & Licensing

Permits in Denver

Building permits in Denver are issued by Community Planning and Development, and contractor licensing here is municipal — a Denver-licensed contractor pulls Denver permits. We handle permit applications and inspections as part of every project. Authority: City and County of Denver — Community Planning and Development.

Permit Thresholds

Denver permit thresholds

Code reference
Drywall patching or replacement of one sheet no larger than 4 ft by 8 ft.
Code/municipal-code references
Requirements are administered under the Denver Building and Fire Code (2025 edition, effective December 31, 2025, incorporating 2024 I-Codes with local amendments; prior editions referenced similar administrative provisions).
Code reference
Exemptions and permit triggers align with administrative sections (e.g., analogous to IBC/IRC Section 105 or city-specific Admin provisions such as those referenced in policy documents like ADMIN 131/138).§105
Code reference
Demolition has a specific reference (Denver Commercial Building Code Section 130.3 for exempted work).§130.3
There is a tiered schedule (e.g., $1–$500
$20 permit fee; higher tiers add per-$1,000 amounts with 50% plan review on many ranges); see the full table in the Development Fees policy for exact tiers.

Codes are amended regularly — verify current requirements with City and County of Denver — Community Planning and Development.

Energy Code

Denver energy code quick facts

Code reference
2021 IECC (with local Denver amendments) as adopted in the 2025 Denver Building and Fire Codes / Denver Energy Code (effective December 31, 2025); Denver Green Code (DGC) provisions may also apply to certain commercial/multifamily projects.
Code reference
Denver (Climate Zone 5B) follows the 2021 IECC base with amendments incorporated into the Denver Energy Code (DEC; residential provisions start around p.
Code reference
312 of the code document).
Code reference
The 2025 adoption explicitly incorporates the 2021 IECC for energy (distinct from the 2024 I-codes used for other building/fire provisions).
Code reference
Chapter 5 [RE] / [CE] addresses additions, alterations, repairs, and changes of occupancy to existing buildings.
Code reference
The DGC (2022, effective ~May 2023) is largely voluntary but includes mandatory elements for some larger buildings alongside Energize Denver performance standards (primarily for existing large buildings).
Code reference
Key prescriptive requirements relevant to remodels/additions (drawn from 2021 IECC Table R402.1.3 / equivalent, applicable via Chapter 5 for new envelope work unless otherwise exempted; Denver-specific checklist references confirm use of these tables or U-factor alternatives):
Ceiling/attic insulation
Minimum R-60 (Climate Zone 5).

Codes are amended regularly — verify current requirements with City and County of Denver — Community Planning and Development.

Zoning & Dimensional Standards

Setback & dimensional standards in Denver

Zone-district dimensional standards for Denver, quoted verbatim from the Denver Zoning Code. Knowing your lot's district — and its setbacks, height, and coverage limits — is where every feasibility conversation starts.

E-CC-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code E-CC-3 setback standards (4.3, p.37) — effective 2010-06-25 · View the code

E-MS-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MS-2 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MS-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MS-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MS-5 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MU-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-MU-2.5 setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-MX-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-2 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-2Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-2A setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-3Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-3A setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-Esetback & dimensional standards
StandardRequirement
Primary Street Setback (min)40% E-MS: 60%
Side Street Setback (min)25%

Denver Zoning Code E-MX-E setback standards (4.3, p.39) — effective 2010-06-25 · View the code

E-RH-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-RH-2.5 setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-RX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-RX-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-RX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-RX-5 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-SU-Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-SU-A setback standards (4.3, p.21) — effective 2010-06-25 · View the code

E-SU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-SU-B setback standards (4.3, p.21) — effective 2010-06-25 · View the code

E-SU-Dsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-SU-D setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-SU-Gsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)9,000 sf
Zone Lot Width (min)62.5'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-SU-G setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-TU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-TU-B setback standards (4.3, p.21) — effective 2010-06-25 · View the code

E-TU-Csetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)3' min one side/ 10' min combined
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)5,500 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-TU-C setback standards (4.3, p.21) — effective 2010-06-25 · View the code

G-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-MS-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-MS-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-MS-5 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-MU-12setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)10'
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'

Denver Zoning Code G-MU-12 setback standards (6.3, p.29) — effective 2010-06-25 · View the code

G-MU-20setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)10'
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'

Denver Zoning Code G-MU-20 setback standards (6.3, p.29) — effective 2010-06-25 · View the code

G-MU-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)3' min one side/10' min combined
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-MU-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-MU-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-MU-5 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-MU-8setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-MU-8 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-MX-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-RH-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)15'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Bulk Plane12'

Denver Zoning Code G-RH-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-RO-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)3' min one side/10' min combined
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-RO-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-RO-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-RO-5 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-RX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-RX-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-RX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-RX-5 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

S-CC-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-CC-3 setback standards (3.3, p.29) — effective 2010-06-25 · View the code

S-CC-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)5'

Denver Zoning Code S-CC-5 setback standards (3.3, p.33) — effective 2010-06-25 · View the code

S-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-MS-3 setback standards (3.3, p.29) — effective 2010-06-25 · View the code

S-MU-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)13.1.5.9 or 20' , whichever
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)37.5'
Height in Feet (max)32'/32'
Height in Stories (max)3/3

Denver Zoning Code S-MU-3 setback standards (3.3, p.21) — effective 2010-06-25 · View the code

S-MX-12setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20' 20'/25'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-12 setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-12Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20' 20'/25'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-12A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-MX-2 setback standards (3.3, p.29) — effective 2010-06-25 · View the code

S-MX-2Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)40% Residential Only Buildings: 30%
Side Street Setback (min)25%
Side Interior Setback (min)0'

Denver Zoning Code S-MX-2A setback standards (3.3, p.37) — effective 2010-06-25 · View the code

S-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-MX-3 setback standards (3.3, p.31) — effective 2010-06-25 · View the code

S-MX-3Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)15'

Denver Zoning Code S-MX-3A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-5 setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-5Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-5A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-8Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'

Denver Zoning Code S-MX-8A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-RH-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)37.5'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code S-RH-2.5 setback standards (3.3, p.21) — effective 2010-06-25 · View the code

S-SU-Asetback & dimensional standards
StandardRequirement
Side Interior Setback (min)3' 5'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code S-SU-A setback standards (3.3, p.19) — effective 2010-06-25 · View the code

S-SU-FAsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10' 5'/15'
Side Interior Setback (min)5'/15'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)8,500 sf
Zone Lot Width (min)62.5'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'

Denver Zoning Code S-SU-FA setback standards (3.3, p.19) — effective 2010-06-25 · View the code

S-SU-Isetback & dimensional standards
StandardRequirement
Side Street Setback (min)5'
Zone Lot Area (min)12,000 sf
Zone Lot Width (min)62.5'
Height in Feet (max)30'/30'
Height in Stories (max)3/3
Bulk Plane10'/10' 10'/10'

Denver Zoning Code S-SU-I setback standards (3.3, p.19) — effective 2010-06-25 · View the code

U-MS-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MS-2 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MS-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MS-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MS-5 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MX-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MX-2 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MX-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-RH-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)10'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-RH-2.5 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-RH-3Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)10'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-RH-3A setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-RX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-RX-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-RX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-RX-5 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-SU-Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-A setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-A2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-A2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-B setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-B2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-B2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Csetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Interior Setback (min)3' min one 10' min combined
Zone Lot Area (min)5,500 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-C setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-C2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3' min one 10' min combined
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)5,500 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-C2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Esetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)7,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-E setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Hsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)10,000 sf
Zone Lot Width (min)75'
Height in Feet (max)30'/17'
Height in Stories (max)3/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-H setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-TU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-TU-B setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-TU-B2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-TU-B2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-TU-Csetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)10'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-TU-C setback standards (5.3, p.19) — effective 2010-06-25 · View the code

Verify current requirements with the jurisdiction — informational reference only. Standards vary by overlay, lot, and use; we confirm the exact rules for your property during feasibility.

text

What this covers

Interior build-out of a leased commercial shell: partitions, finishes, lighting, and MEP coordination. Work follows the landlord criteria and Denver commercial permit path.

text

How the work is coordinated

A municipally licensed Denver general contractor coordinates licensed specialty trades. Denver-metro work is permitted locally. Colorado has no statewide general-contractor license. Cities and counties license general contractors. DORA licenses electrical and plumbing (and similar regulated trades), not general contractors. Autotelic is a municipally licensed Denver general contractor that coordinates licensed specialty trades. Denver building permits run through Community Planning and Development (CPD). Costs are project-specific; no dollar figures.

Service Area

Serving Denver and Denver County

We serve Denver, CO and all surrounding Denver metro communities. Our team is based in Denver and operates throughout the Front Range, from Castle Rock to Longmont and everywhere in between. Contact us for a free estimate on your Denver project.

FAQ

Common questions

How much does Commercial TI Walkthrough cost in Denver?

$350.

How do I book?

Press Book next to the job, pick a date and a morning (8–12) or afternoon (12–4) window, and pay in full. We confirm within 24 hours or refund you in full.

Do you work with multi-site brands and facility programs?

Yes — we run build-outs, refresh programs, and tenant improvements for commercial clients across the Front Range, including recurring facilities work for national brands.

Who handles the permits for a tenant finish?

We do. Commercial permits are issued by the municipality where the space sits, and our team manages drawings, submittals, and inspections through sign-off.

How do you keep a build-out on schedule?

Every project runs on our own operations platform — schedule, submittals, and status updates in one system — so you get straight answers about where things stand, in minutes not days.

How It Runs

01

Survey

02

Design

03

Build

04

Verify

DESIGN SERVICES

CONSTRUCTION

TECHNOLOGY

Free Estimate

Get a free commercial tenant finish estimate in Denver

Tell us about your Denver project — we respond fast, and estimates are always free.

Name, phone, and email required.

Verifying you're human…