(720) 287-7958

DESIGN · BUILD · AUTOMATE

ENGLEWOOD SERVICES

Garage Conversion in Englewood

ADU Feasibility Consultation, $350

See all 2 jobs

Licensed garage conversion services for Englewood and Arapahoe County. Turn your garage into livable space.

What Englewood requires

R-1-A — Minimum Lot Area: 9000 sf R-1-A

See full local requirements ↓
  • Full Design Lifecycle
  • Construction & Tenant Finish
  • Smart Home · A/V · Edge Compute
Garage Conversion

Turn your garage into livable space

Jobs you can book online

Pick your job and choose a time.

Pay when you book. We confirm within 24 hours or refund you in full.

  • ADU Feasibility Consultation

    An on-site review of your lot against local ADU zoning, setbacks, and utility access.

    Pay when you book · morning (8–12) or afternoon (12–4)

    What's included

    An on-site review of your lot against local ADU zoning, setbacks, and utility access. You get a verbal go/no-go read plus a one-page summary of constraints and next steps.

  • ADU Feasibility Package

    Site visit plus a written feasibility report: local ADU zoning check, buildable envelope sketch, utility routing notes, and a preliminary budget.

    $475 deposit to book, the rest when the work is done · morning (8–12) or afternoon (12–4)

    What's included

    Site visit plus a written feasibility report: local ADU zoning check, buildable envelope sketch, utility routing notes, and a preliminary budget. A documented go/no-go you can take to a lender.

FREE PLANNING TOOLS

Both tools are free and take a couple of minutes — start in either one.

Local Service

Garage Conversion Services in Englewood, Colorado

Autotelic provides professional garage conversion services throughout Englewood and the surrounding Arapahoe County area. Garage to living space conversions across the Denver metro — studios, offices, guest suites, and ADUs with full HVAC, insulation, and code-compliant egress. Whether you're in Englewood (south central Denver metro) or nearby communities, our team delivers quality workmanship, licensed and insured.

Permit Thresholds

Englewood permit thresholds

Code reference
In Englewood, Colorado, building permits for residential remodel work are generally required based on the specific type of work performed rather than a fixed valuation threshold. The City requires permits for most construction projects to ensure compliance with adopted building codes (including
Code reference
Repair of roofing or siding when the repaired area is less than 100 square feet.
Code reference
Decks under 200 square feet that are not attached to the house, do not serve an exit door, and are not more than 30 inches above grade (zoning approval still required).
Code reference
The City’s use tax rate is 3.80% applied to 50% of the project valuation (an estimate assuming 50% of valuation represents taxable construction materials).
Code reference
A reconciliation process is available post-project if actual materials differ from the 50% estimate.
Code reference
Relevant references include the City’s “To Permit or Not To Permit” guidance and the Sales, Use and Other Taxes page (with citations to EMC Title 4, Chapter 4 for sales/use tax rules).

Codes are amended regularly — verify current requirements with **The City of Englewood’s Building and Codes Division (part of the Community Development Department) issues residential building permits.

Zoning & ADU

Englewood zoning & ADU quick facts

R-1-A — Minimum Lot Area
9000 sfR-1-A
R-1-A — Minimum Lot Width
75'R-1-A
R-1-A — Front Setback (min)
25'R-1-A
R-1-A — Side Interior Setback (min)
7'R-1-A
R-1-A — Rear Setback (min)
20'R-1-A
R-1-A — Lot Coverage (max)
40%R-1-A
R-1-A — Building Height (max)
30'R-1-A
R-1-A — Bulk Plane Front 60% Height at Side Lot (Table 5-5)
12'R-1-A
Englewood Municipal Code Title 16 UDC §16-5-3 Table 5-2 (current through Mar 18, 2026) R-1-A setback standards (Table 5-2 Residential Building and Lot Standards) — effective 2026-03-18Source: library.municode.com

Codes are amended regularly — verify current requirements with **The City of Englewood’s Building and Codes Division (part of the Community Development Department) issues residential building permits.

Energy Code

Englewood energy code quick facts

Code reference
2024 International Energy Conservation Code (IECC), adopted by the City of Englewood with no specific local amendments detailed on the official building division page (effective for all permits submitted after May 31, 2026).
Code reference
This applies to the Denver-metro area (Climate Zone 5B).
Code reference
Key prescriptive requirements from the 2024 IECC (relevant to remodels/additions via the residential or existing-building provisions, e.g., R402 and related sections) include the following (standard base-code values, as no local amendments are specified):
Code reference
Vertical fenestration U-factor ≤ 0.28 (Table R402.1.2, Climate Zone 5 and Marine 4).
Code reference
Skylight U-factor ≤ 0.50 (Table R402.1.2, Climate Zone 5 and Marine 4).
Code reference
Air leakage ≤ 3.0 ACH50 at 50 Pa for detached one-family dwellings in Climate Zones 3–5 (or ≤ 0.27 cfm/ft² of enclosure area for smaller homes/attached units); testing required (R402.4.1.2).
Code reference
Additional common prescriptive envelope items (from 2024 IECC Tables R402.1.2/R402.1.3 for CZ 5) typically cover ceiling/attic, wall, and other assemblies, but exact R-values/U-factors should be verified directly from the adopted code edition as they involve trade-offs and footnotes.

Codes are amended regularly — verify current requirements with **The City of Englewood’s Building and Codes Division (part of the Community Development Department) issues residential building permits.

text

What garage conversion covers

Garage conversions in the Denver metro turn an attached or detached garage into conditioned living space or, where zoning allows, an accessory dwelling unit. Work typically includes insulation, new openings, electrical, HVAC, and often a bath or kitchen. Parking on the lot still has to satisfy zoning. A municipally licensed Denver general contractor coordinates the project and licensed specialty trades. Cost is project-specific and depends on attached versus detached, ADU versus extra rooms, and how much of the envelope changes.

text

What buyers should prepare

Attached versus detached, living space versus ADU, whether a bath or kitchen is included, and how parking will be handled.

FAQ

Common questions

How much does ADU Feasibility Consultation cost in Englewood?

$350.

How do I book?

Press Book next to the job, pick a date and a morning (8–12) or afternoon (12–4) window, and pay in full. We confirm within 24 hours or refund you in full.

Who handles garage conversion permits and licensing?

A municipally licensed Denver general contractor coordinates the project, design professionals, and specialty trades. Colorado has no statewide general contractor license.

Is extra living space the same as an ADU?

No. Extra rooms for the main house stay one dwelling. An ADU is a separate dwelling and is only allowed in districts that permit it.

What information helps define scope?

Attached vs detached, ADU vs extra rooms, parking plan, and city or county.

Service Area

Serving Englewood and Arapahoe County

We serve Englewood, CO and all surrounding Denver metro communities. Our team is based in Denver and operates throughout the Front Range, from Castle Rock to Longmont and everywhere in between. Contact us for a free estimate on your Englewood project.

How It Runs

01

Survey

02

Design

03

Build

04

Verify

DESIGN SERVICES

CONSTRUCTION

TECHNOLOGY