autotelic.build

DESIGN · BUILD · AUTOMATE

DENVER SERVICES

Custom Cabinetry in Denver

Licensed custom cabinetry services for Denver and Denver County. Storage that works and looks great.

  • Full Design Lifecycle
  • Construction & Tenant Finish
  • Smart Home · A/V · Edge Compute
Custom Cabinetry project — Denver metro

Storage that works and looks great

Local Service

Custom Cabinetry Services in Denver, Colorado

Autotelic provides professional custom cabinetry services throughout Denver and the surrounding Denver County area. Custom cabinetry across the Denver metro — kitchen, bath, closet, and built-in cabinets from stock to full-custom with soft-close hardware and organizational inserts. Whether you're in Denver (Colorado's capital city) or nearby communities, our team delivers quality workmanship backed by Colorado licensing and full insurance coverage.

Permits & Licensing

Permits in Denver

Building permits in Denver are issued by Community Planning and Development, and contractor licensing here is municipal — a Denver-licensed contractor pulls Denver permits. We handle permit applications and inspections as part of every project. Authority: City and County of Denver — Community Planning and Development.

Permit Thresholds

Denver permit thresholds

Code reference
Drywall patching or replacement of one sheet no larger than 4 ft by 8 ft.
Code/municipal-code references
Requirements are administered under the Denver Building and Fire Code (2025 edition, effective December 31, 2025, incorporating 2024 I-Codes with local amendments; prior editions referenced similar administrative provisions).
Code reference
Exemptions and permit triggers align with administrative sections (e.g., analogous to IBC/IRC Section 105 or city-specific Admin provisions such as those referenced in policy documents like ADMIN 131/138).Section 105
Code reference
Demolition has a specific reference (Denver Commercial Building Code Section 130.3 for exempted work).Section 130.3
There is a tiered schedule (e.g., $1–$500
$20 permit fee; higher tiers add per-$1,000 amounts with 50% plan review on many ranges); see the full table in the Development Fees policy for exact tiers.

Codes are amended regularly — verify current requirements with City and County of Denver — Community Planning and Development.

Energy Code

Denver energy code quick facts

Code reference
2021 IECC (with local Denver amendments) as adopted in the 2025 Denver Building and Fire Codes / Denver Energy Code (effective December 31, 2025); Denver Green Code (DGC) provisions may also apply to certain commercial/multifamily projects.
Code reference
Denver (Climate Zone 5B) follows the 2021 IECC base with amendments incorporated into the Denver Energy Code (DEC; residential provisions start around p.
Code reference
312 of the code document).
Code reference
The 2025 adoption explicitly incorporates the 2021 IECC for energy (distinct from the 2024 I-codes used for other building/fire provisions).
Code reference
Chapter 5 [RE] / [CE] addresses additions, alterations, repairs, and changes of occupancy to existing buildings.
Code reference
The DGC (2022, effective ~May 2023) is largely voluntary but includes mandatory elements for some larger buildings alongside Energize Denver performance standards (primarily for existing large buildings).
Code reference
Key prescriptive requirements relevant to remodels/additions (drawn from 2021 IECC Table R402.1.3 / equivalent, applicable via Chapter 5 for new envelope work unless otherwise exempted; Denver-specific checklist references confirm use of these tables or U-factor alternatives):
Ceiling/attic insulation
Minimum R-60 (Climate Zone 5).

Codes are amended regularly — verify current requirements with City and County of Denver — Community Planning and Development.

Zoning & Dimensional Standards

Setback & dimensional standards in Denver

Zone-district dimensional standards for Denver, quoted verbatim from the Denver Zoning Code. Knowing your lot's district — and its setbacks, height, and coverage limits — is where every feasibility conversation starts.

E-CC-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code E-CC-3 setback standards (4.3, p.37) — effective 2010-06-25 · View the code

E-MS-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MS-2 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MS-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MS-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MS-5 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MU-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-MU-2.5 setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-MX-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-2 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-2Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-2A setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-3Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-MX-3A setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-MX-Esetback & dimensional standards
StandardRequirement
Primary Street Setback (min)40% E-MS: 60%
Side Street Setback (min)25%

Denver Zoning Code E-MX-E setback standards (4.3, p.39) — effective 2010-06-25 · View the code

E-RH-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-RH-2.5 setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-RX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-RX-3 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-RX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code E-RX-5 setback standards (4.3, p.33) — effective 2010-06-25 · View the code

E-SU-Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-SU-A setback standards (4.3, p.21) — effective 2010-06-25 · View the code

E-SU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-SU-B setback standards (4.3, p.21) — effective 2010-06-25 · View the code

E-SU-Dsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-SU-D setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-SU-Gsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)9,000 sf
Zone Lot Width (min)62.5'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code E-SU-G setback standards (4.3, p.19) — effective 2010-06-25 · View the code

E-TU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-TU-B setback standards (4.3, p.21) — effective 2010-06-25 · View the code

E-TU-Csetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)3' min one side/ 10' min combined
Rear Setback where no alley (min)12' 12' 20' 20' 20'
Rear Setback where alley abuts (min)3' 5' 5' 7.5' 3' 3' min one side/ 10' min com- bined 5' 10'
Building Coverage (max)45%
Zone Lot Area (min)5,500 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code E-TU-C setback standards (4.3, p.21) — effective 2010-06-25 · View the code

G-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-MS-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-MS-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-MS-5 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-MU-12setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)10'
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'

Denver Zoning Code G-MU-12 setback standards (6.3, p.29) — effective 2010-06-25 · View the code

G-MU-20setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)10'
Zone Lot Area (min)6,000 sf
Zone Lot Width (min)50'

Denver Zoning Code G-MU-20 setback standards (6.3, p.29) — effective 2010-06-25 · View the code

G-MU-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)3' min one side/10' min combined
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-MU-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-MU-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-MU-5 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-MU-8setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)7.5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-MU-8 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-MX-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-RH-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)15'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Bulk Plane12'

Denver Zoning Code G-RH-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-RO-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)3' min one side/10' min combined
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-RO-3 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-RO-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'

Denver Zoning Code G-RO-5 setback standards (6.3, p.17) — effective 2010-06-25 · View the code

G-RX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-RX-3 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

G-RX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code G-RX-5 setback standards (6.3, p.27) — effective 2010-06-25 · View the code

S-CC-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-CC-3 setback standards (3.3, p.29) — effective 2010-06-25 · View the code

S-CC-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)5'

Denver Zoning Code S-CC-5 setback standards (3.3, p.33) — effective 2010-06-25 · View the code

S-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-MS-3 setback standards (3.3, p.29) — effective 2010-06-25 · View the code

S-MU-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)13.1.5.9 or 20' , whichever
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)37.5'
Height in Feet (max)32'/32'
Height in Stories (max)3/3

Denver Zoning Code S-MU-3 setback standards (3.3, p.21) — effective 2010-06-25 · View the code

S-MX-12setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20' 20'/25'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-12 setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-12Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20' 20'/25'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-12A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-MX-2 setback standards (3.3, p.29) — effective 2010-06-25 · View the code

S-MX-2Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)40% Residential Only Buildings: 30%
Side Street Setback (min)25%
Side Interior Setback (min)0'

Denver Zoning Code S-MX-2A setback standards (3.3, p.37) — effective 2010-06-25 · View the code

S-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)0'
Side Street Setback (min)0'
Side Interior Setback (min)0'

Denver Zoning Code S-MX-3 setback standards (3.3, p.31) — effective 2010-06-25 · View the code

S-MX-3Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)15'

Denver Zoning Code S-MX-3A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-5 setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-5Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'
Side Interior Setback (min)35'/40'

Denver Zoning Code S-MX-5A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-MX-8Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)20'

Denver Zoning Code S-MX-8A setback standards (3.3, p.39) — effective 2010-06-25 · View the code

S-RH-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)37.5'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code S-RH-2.5 setback standards (3.3, p.21) — effective 2010-06-25 · View the code

S-SU-Asetback & dimensional standards
StandardRequirement
Side Interior Setback (min)3' 5'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'/10'

Denver Zoning Code S-SU-A setback standards (3.3, p.19) — effective 2010-06-25 · View the code

S-SU-FAsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10' 5'/15'
Side Interior Setback (min)5'/15'
Rear Setback where alley abuts (min)12'
Building Coverage (max)50%
Zone Lot Area (min)8,500 sf
Zone Lot Width (min)62.5'
Height in Feet (max)30'/30'
Height in Stories (max)2.5/2.5
Bulk Plane10'

Denver Zoning Code S-SU-FA setback standards (3.3, p.19) — effective 2010-06-25 · View the code

S-SU-Isetback & dimensional standards
StandardRequirement
Side Street Setback (min)5'
Zone Lot Area (min)12,000 sf
Zone Lot Width (min)62.5'
Height in Feet (max)30'/30'
Height in Stories (max)3/3
Bulk Plane10'/10' 10'/10'

Denver Zoning Code S-SU-I setback standards (3.3, p.19) — effective 2010-06-25 · View the code

U-MS-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MS-2 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MS-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MS-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MS-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MS-5 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MX-2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MX-2 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-MX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-MX-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-RH-2.5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)10'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-RH-2.5 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-RH-3Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)10'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-RH-3A setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-RX-3setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-RX-3 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-RX-5setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)7.5'
Side Interior Setback (min)5'

Denver Zoning Code U-RX-5 setback standards (5.3, p.27) — effective 2010-06-25 · View the code

U-SU-Asetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-A setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-A2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-A2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-B setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-B2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-B2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Csetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Interior Setback (min)3' min one 10' min combined
Zone Lot Area (min)5,500 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-C setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-C2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3' min one 10' min combined
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)5,500 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-C2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Esetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)7,000 sf
Zone Lot Width (min)50'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-E setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-SU-Hsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)5'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)45%
Zone Lot Area (min)10,000 sf
Zone Lot Width (min)75'
Height in Feet (max)30'/17'
Height in Stories (max)3/1
Bulk Plane17'/10'

Denver Zoning Code U-SU-H setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-TU-Bsetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-TU-B setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-TU-B2setback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)3'
Side Interior Setback (min)3'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)60%
Zone Lot Area (min)3,000 sf
Zone Lot Width (min)25'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-TU-B2 setback standards (5.3, p.19) — effective 2010-06-25 · View the code

U-TU-Csetback & dimensional standards
StandardRequirement
Primary Street Setback (min)10'
Side Street Setback (min)5'
Side Interior Setback (min)10'
Rear Setback where no alley (min)20'
Rear Setback where alley abuts (min)12'
Building Coverage (max)40%
Zone Lot Area (min)4,500 sf
Zone Lot Width (min)35'
Height in Feet (max)30'/17'
Height in Stories (max)2.5/1
Bulk Plane17'/10'

Denver Zoning Code U-TU-C setback standards (5.3, p.19) — effective 2010-06-25 · View the code

Verify current requirements with the jurisdiction — informational reference only. Standards vary by overlay, lot, and use; we confirm the exact rules for your property during feasibility.

text

What Custom Cabinetry Covers

In the Denver metro area, custom cabinetry means design, fabrication, and installation of made-to-order cabinets, millwork, and built-ins—not stock or semi-custom units from a catalog. Typical projects include kitchens, bathroom vanities, home offices, mudrooms, and other storage or display built-ins. Work usually starts with site measurements and design consultations, then moves to detailed drawings that specify dimensions, construction methods, hardware, and finishes, followed by shop fabrication and on-site installation. Custom work is especially useful in older Denver homes where spaces are irregular and off-the-shelf boxes may not fit cleanly.

text

Typical Scope of Work

A custom cabinetry project commonly includes precise field measuring, design development and drawings, material and finish selection, fabrication (often with CNC machining for consistency), and installation. Many shops can work to tight dimensional tolerances so cabinets align with existing walls, floors, and openings. Scope can also cover face frames, doors, drawers, open shelving, panels, and related trim. When a remodel also moves plumbing or electrical fixtures—or changes structure—those items fall outside pure cabinetry and may require separate coordination and permits.

text

Materials and Construction Methods

Durable cabinet boxes are often built with 3/4-inch veneer-core plywood for sides, tops, bottoms, and shelves. Solid hardwoods such as maple, oak, cherry, or hickory are commonly used for face frames, doors, and trim. Painted components may use engineered materials like MDF where a smooth finish is the priority. For structural performance and moisture resistance, many buyers prefer plywood cases over particleboard. Construction may be framed (face-frame) or frameless (European-style), with joinery such as dadoes, rabbets, or splines. Door styles include full-overlay, inset, and related configurations. Soft-close hinges and full-extension drawer slides are common hardware choices. Finishes typically include stains, enamel paints, or clear protective coats applied for consistency and durability.

text

Permits and Code Considerations in Denver

For projects in the City and County of Denver, Community Planning and Development (CPD) handles plan review and permits through the e-permits system. Replacing like-for-like existing cabinets, countertops, or similar cosmetic items generally does not require a permit. Permits are required when work includes structural changes, floor-plan alterations, or new or relocated electrical or plumbing fixtures, and trade permits may apply for those disciplines. Inspections follow the permit type. Historic districts or landmarks may need additional review, and floodplain properties can have extra drainage or sewer-related requirements. Surrounding metro jurisdictions set their own rules, so site-specific confirmation with the local authority having jurisdiction is important. Denver has adopted the 2024 International Codes with local amendments; cabinetry itself does not usually have dedicated prescriptive cabinet-only code sections, but any associated structural, electrical, plumbing, mechanical, fire-resistance, or egress work must comply with applicable building and fire codes.

text

What Buyers Should Evaluate

Compare construction details, not just door style. Prioritize case materials suited to long-term use, confirm hardware quality and load ratings, and review finish samples under lighting similar to your space. Verify that drawings capture exact dimensions and how the cabinets will handle out-of-square walls or floors. Ask about local fabrication, lead times, moisture-aware detailing for Colorado indoor conditions, and what is included versus excluded in the bid. For remodels, confirm whether the scope triggers permits and whether historic-district rules apply. Multiple detailed bids with clear material and method specifications make side-by-side comparison more reliable. Cost is project-specific and depends on size, materials, complexity, finish level, and installation conditions.

text

How a General Contractor Coordinates Custom Cabinetry

As a municipally licensed Denver general contractor, we coordinate custom cabinetry work as part of a broader remodel or as a focused millwork project. That can include sequencing measurements and design, coordinating fabrication and install, and aligning any related electrical, plumbing, or structural work with licensed specialty trades when those scopes apply. Permit strategy depends on the actual scope: cosmetic cabinet replacement may not need a permit, while fixture moves or structural changes typically do. Clear drawings, material specs, and jobsite logistics help keep fabrication and installation aligned with the rest of the project.

FAQ

Common questions

What is the difference between custom, semi-custom, and stock cabinets?

Custom cabinetry is designed and built to order for your space, materials, and details. Semi-custom usually starts from a manufacturer’s standardized boxes and options with limited size flexibility. Stock cabinets are pre-built in fixed sizes and styles. Custom work is often chosen when rooms are irregular, storage needs are specific, or finishes and details need to match an existing home.

Do I need a permit to replace kitchen or bathroom cabinets in Denver?

In the City and County of Denver, replacing like-for-like cabinets or countertops as a cosmetic update generally does not require a permit. A permit is typically required if the project involves structural changes, floor-plan alterations, or new or relocated electrical or plumbing fixtures. Always confirm with Community Planning and Development or the local authority for your address, especially in historic districts.

Who handles the cabinetry-related permits and licensing?

A municipally licensed Denver general contractor coordinates the overall project and works with licensed specialty trades when electrical, plumbing, mechanical, or other permitted scopes are involved. Homeowners may apply for some permits under eligibility rules, while contractors must be properly licensed or registered for the work they perform. Final permit needs depend on the project scope and jurisdiction.

Which cabinet box materials hold up better over time?

Many high-quality custom shops use 3/4-inch plywood for cabinet boxes because it generally offers stronger screw holding and better moisture performance than particleboard. Solid hardwoods are common for face frames and doors. Painted parts may use MDF for a smooth finish. The right mix depends on use, finish, and location in the home.

Framed or frameless—what should I choose?

Framed (face-frame) cabinets use a hardwood frame on the front of the box and are common in traditional styles. Frameless (European-style) cabinets maximize interior access and support full-overlay doors for a cleaner look. Choice is mostly about aesthetics, hardware preferences, and how you want the cabinets to open and function.

How long does a custom cabinetry project take?

Timelines vary with design complexity, material availability, shop schedule, finish process, and whether other remodel trades are involved. Custom work usually includes measurement, design approval, fabrication, finishing, and installation phases. Ask for a schedule based on your drawings and selections rather than a generic estimate.

What should be in a custom cabinet bid?

Look for clear notes on case materials, door and drawer construction, hardware brands or grades, finish system, inclusions such as panels and trim, exclusions, lead time, installation responsibilities, and how site conditions will be handled. Detailed specs make it easier to compare proposals fairly.

Service Area

Serving Denver and Denver County

We serve Denver, CO and all surrounding Denver metro communities. Our team is based in Denver and operates throughout the Front Range, from Castle Rock to Longmont and everywhere in between. Contact us for a free estimate on your Denver project.

How It Runs

01

Survey

02

Design

03

Build

04

Verify

DESIGN SERVICES

CONSTRUCTION

TECHNOLOGY

TRUSTED TO BUILD FOR

  • Punch Bowl SocialFirst four locations
  • Spectrum RetirementSenior living communities
  • Denver HighlandsFirst modular custom home

Free Estimate

Get a free custom cabinetry estimate in Denver

Tell us about your Denver project — we respond fast, and estimates are always free.

Name, phone, and email required.